press the UP switch without pressing ARM and check for no trim response. Do the same with
the DN switch. NOTE: An active UP or DN switch without ARM will trip a latent switch failure
monitor after three seconds. For SW MOD 01/05 software or later, “PT” will be annunciated on
the KC 140 and MET operation will be disabled until all three MET switch inputs are inactive.
For earlier versions, “PT” will be annunciated on the KC 140 and MET operation will be disabled
until the fault is cleared and unit power is cycled.